• Телефон отдела продаж: 8 (800) 700-25-97
  • Email: sales@prompc.info
  • Санкт-Петербург, ул. Софийская,14, Бизнес-центр

Шлюз Modbus выступает в качестве интерфейса между устройствами с последовательным интерфейсом и компьютером благодаря сети Ethernet и протоколу Modbus/TCP. Являясь полностью совместимым с протоколом Modbus/TCP, сервер последовательных интерфейсов Modbus представляет собой удобное решение для подключения существующих модулей или контроллеров на базе последовательного протокола Modbus (Modbus/ASCII или Modbus/RTU) к сети Ethernet.

EKI-1221

1-port Modbus Gateway
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Supports 31 slaves per serial port
  • Easy-managing Advantech Serial Device Server Configuration Utility for Windows 2000/XP/Vista/7
  • Auto searching slave ID over configuration utility
  • Software selectable RS-232/422/485 communication
  • Mounts on DIN-rail, wall or panel
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control

EKI-1221I

1-port Modbus Gateway with Wide Temperature
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Auto searching slave ID over configuration utility
  • Software selectable RS-232/422/485 communication
  • Mounts on DIN-rail and Wall mount
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control
  • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
  • Wide operating temperature

EKI-1221CI

1-port Modbus Gateway with Isolation and Wide Temperature
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Auto searching slave ID over configuration utility
  • Software selectable RS-232/422/485 communication
  • Mounts on DIN-rail and Wall mount
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control
  • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
  • Support isolation and wide operating temperature

The EKI-1200 series Modbus gateways are bi-directional gateways for integrating new and existing Modbus/RTU and Modbus/ASCII serial devices to newer TCP/IP networked-based devices. The EKI-1221/1222/1224 feature two independent Ethernet ports and MAC addresses to provide a redundant networking mechanism to guarantee Ethernet networking reliability. They provide a simple and cost-effective way to bring the advantage of remote management and data accessibility to thousand of devices that can not connect to a network. The EKI-1221/1222/1224 provide a feature that can allow users to select master or slave operation mode for each serial port. They not only allow an Ethernet master to control serial slaves, but also allow serial masters to control Ethernet slaves.

EKI-1221D

1-port Modbus Gateway with Integrated Ethernet Cascading
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for Daisy Chian connectivity
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports Ethernet auto-bypass function
  • Master mode supports 32 TCP slaves at the same time
  • Slave mode supports up to 16 TCP masters
  • Supports mapping Modbus slave ID option
  • Auto searching Modbus slave ID over configuration utility
  • Mounts on DIN-rail, wall or panel
  • Class I, Division 2 certification

The EKI-1200 series Modbus gateways are bi-directional gateways for integrating new and existing Modbus/RTU and Modbus/ASCII serial devices to newer TCP/IP networked-based devices. The EKI-1221D/1222D feature two Ethernet ports with one IP address for easier network wiring. One port can be used to connect to the network, and the other port can be used to connect to another Ethernet device or another EKI-1221D/1222D. They provide a simple and cost-effective way to bring the advantage of remote management and data accessibility to thousand of devices that can not connect to a network. The EKI-1221D/1222D provide a feature that can allow users to select master or slave operation mode for each serial port. They not only allow an Ethernet master to control serial slaves, but also allow serial masters to control Ethernet slaves.

EKI-1222

2-port Modbus Gateway
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Supports 31 slaves per serial port
  • Easy-managing Advantech Serial Device Server Configuration Utility for Windows 2000/XP/Vista/7
  • Auto searching slave ID over configuration utility
  • Software selectable RS-232/422/485 communication
  • Mounts on DIN-rail, wall or panel
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control

EKI-1222I

2-port Modbus Gateway with Wide Temperature
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Auto searching slave ID over configuration utility
  • Software selectable RS-232/422/485 communication
  • Mounts on DIN-rail and Wall mount
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control
  • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
  • Support a wide operating temperature

EKI-1222CI

2-port Modbus Gateway with Isolation and Wide Temperature
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Auto searching slave ID over configuration utility
  • Software selectable RS-232/422/485 communication
  • Mounts on DIN-rail and Wall mount
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control
  • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
  • Support isolation and wide operating temperature

The EKI-1200 series Modbus gateways are bi-directional gateways for integrating new and existing Modbus/RTU and Modbus/ASCII serial devices to newer TCP/IP networked-based devices. The EKI-1221/1222/1224 feature two independent Ethernet ports and MAC addresses to provide a redundant networking mechanism to guarantee Ethernet networking reliability. They provide a simple and cost-effective way to bring the advantage of remote management and data accessibility to thousand of devices that can not connect to a network. The EKI-1221/1222/1224 provide a feature that can allow users to select master or slave operation mode for each serial port. They not only allow an Ethernet master to control serial slaves, but also allow serial masters to control Ethernet slaves.

EKI-1222D

2-port Modbus Gateway with Integrated Ethernet Cascading
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for Daisy Chian connectivity
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports Ethernet auto-bypass function
  • Master mode supports 32 TCP slaves at the same time
  • Slave mode supports up to 16 TCP masters
  • Supports mapping Modbus slave ID option
  • Auto searching Modbus slave ID over configuration utility
  • Mounts on DIN-rail, wall or panel
  • Class I, Division 2 certification

The EKI-1200 series Modbus gateways are bi-directional gateways for integrating new and existing Modbus/RTU and Modbus/ASCII serial devices to newer TCP/IP networked-based devices. The EKI-1221D/1222D feature two Ethernet ports with one IP address for easier network wiring. One port can be used to connect to the network, and the other port can be used to connect to another Ethernet device or another EKI-1221D/1222D. They provide a simple and cost-effective way to bring the advantage of remote management and data accessibility to thousand of devices that can not connect to a network. The EKI-1221D/1222D provide a feature that can allow users to select master or slave operation mode for each serial port. They not only allow an Ethernet master to control serial slaves, but also allow serial masters to control Ethernet slaves.

EKI-1224

4-port Modbus Gateway
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Supports 31 slaves per serial port
  • Easy-managing Advantech Serial Device Server Configuration Utility for Windows 2000/XP/Vista/7
  • Auto searching slave ID over configuration utility
  • Mounts on DIN-rail, wall or panel
  • Software selectable RS-232/422/485 communication
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control

EKI-1224I

4-port Modbus Gateway with Wide Temperature
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Auto searching slave ID over configuration utility
  • Software selectable RS-232/422/485 communication
  • Mounts on DIN-rail and Wall mount
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control
  • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
  • Support a wide operating temperature

EKI-1224CI

4-port Modbus Gateway with Isolation and Wide Temperature
 
 
  • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
  • Integration of Modbus TCP and Modbus RTU/ASCII networks
  • Supports up to 921.6 kbps, and any baud rate setting
  • Supports up to 16 connections and 32 requests simultaneously
  • Auto searching slave ID over configuration utility
  • Software selectable RS-232/422/485 communication
  • Mounts on DIN-rail and Wall mount
  • Built-in 15 KV ESD protection for all serial signals
  • Automatic RS-485 data flow control
  • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
  • Support isolation and wide operating temperature

The EKI-1200 series Modbus gateways are bi-directional gateways for integrating new and existing Modbus/RTU and Modbus/ASCII serial devices to newer TCP/IP networked-based devices. The EKI-1221/1222/1224 feature two independent Ethernet ports and MAC addresses to provide a redundant networking mechanism to guarantee Ethernet networking reliability. They provide a simple and cost-effective way to bring the advantage of remote management and data accessibility to thousand of devices that can not connect to a network. The EKI-1221/1222/1224 provide a feature that can allow users to select master or slave operation mode for each serial port. They not only allow an Ethernet master to control serial slaves, but also allow serial masters to control Ethernet slaves.

ADAM-4572

Шлюз передачи данных от порта RS-232/422/485 с протоколом Modbus в сеть Ethernet
 
 
  • Скорость передачи данных 10/100 Мбит/с
  • Возможность предоставления доступа к данным для 8 опрашивающих устройств одновременно
  • Совместимость с ПО для средств ЧМИ c поддержкой протокола Modbus/TCP или OPC-сервера
  • Поддержка 3-х независимых последовательных портов при работе в RS-485 режиме
  • Наличие утилиты под ОС Windows для автоматического обнаружения подключенных устройств
  • Защита от перенапряжения на линиях передачи данных по протоколу RS-485 и подачи питания
  • Автоматический контроль передачи данных по интерфейсу RS-485
  • Легкость установки на DIN рельс или в панель или ярусно
  • Поддержка протоколов Modbus/ASCII, RTU для управления устройствами
Яндекс.Метрика
ПОЗВОНИТЕ МНЕ
+
Жду звонка!